https://docs.google.com/presentation/d/1f7yzu_eQjDk5VdvkUQRAX47C09QUH0AC/edit?usp=sharing&ouid=108938057700723052405&rtpof=true&sd=true
I AM A CIVIL ENGINEER AND TEACHING FOR THE PAST 34 YEARS AS OF NOW AND AM SHARING MY EXPERIENCE'S RIGHT FROM THE BEGINNING AS A ENGINEERING STUDENT WITH MAINLY EDUCATIONAL SUBJECTS RELATED TO CIVIL ENGINEERING THE MAIN MOTIVE IS TO KEEP THE PRACTICAL ASPECT CLEAR and moving for civil engineers RECENTLY I HAVE TAKEN OTHER SUBJECTS TOO LIKE CHEMISTRY WORKSHOP TECHNOLOGY etc
About Me YOU THINK I WILL DO IT
- @Engineers India Solutions
- I AM A CIVIL ENGINEERING BY PROFESSION '34 YEAR'S OF EXPERIENCE PROVIDING PRACTICAL AND FIELD KNOWLEDGE ' MOSTLY FIELD WORK CRAZE FOR CIVIL WORK OR SAY ONSITE WORKhttps://engineersindiasolutions.wordpress.com/ WEBSITE
Sunday, 9 October 2022
THEODOLITE progress.ppt
Saturday, 10 September 2022
प्रयोग संख्या 1:--क्षैतिज कोण को सामान्य विधि से मापना :--थियोडोलाइट की सहायता से
प्रयोग संख्या-1
ओब्जेक्ट : क्षैतिज कोण को सामान्य विधि से मापना। उपकरण: स्टैंड के साथ थियोडोलाइट, छड़ें लेकर। वी
क्षैतिज कोण को मापने की सीधी या सामान्य विधि पर विचार करें
चित्र -1 ) मान लीजिए कि कोण AOB को मापा जाना है। निम्नलिखित
प्रक्रिया अपनाई जाती है।
प्रक्रिया:
1. उपकरण को 0 पर सेट करें।
(इसका मतलब है कि केंद्रीकरण और समतलन पूरी तरह से किया गया) बी
2. लंबवत सर्कल को बाईं स्थिति में रखें। चित्र 5.1
3. लोअर क्लैंप को रखकर फिक्स किया जाता है। ऊपरी क्लैंप ढीला है और द्वारा
दूरबीन को दक्षिणावर्त घुमाते हुए, वर्नियर A को 00 पर और वर्नियर B को लगभग 180° पर सेट किया जाता है।
4. ऊपरी क्लैंप को फिर कड़ा कर दिया जाता है। अब ऊपरी स्पर्शरेखा पेंच को मोड़कर, वर्नियर A और B को पर सेट किया जाता है
आवर्धक काँच से देखने पर ठीक 0° और 180°।
5. ऊपरी क्लैंप को स्थिर रखकर, निचले हिस्से को ढीला करें और दूरबीन को बाईं ओर की ओर निर्देशित किया जाता है। ई.ए.
6. दूरदर्शी को ठीक से फोकस करके और लंबन को हटाकर रेंजिंग रॉड A को लगभग द्विभाजित किया जाता है।
7. अब निचले क्लैंप को कड़ा कर दिया गया है और रेंज ए रॉड को सटीक रूप से द्विभाजित किया गया है।
8. निचले क्लैंप को स्थिर रखने से ऊपरी क्लैंप ढीला हो जाता है।
9. दूरदर्शी को दक्षिणावर्त घुमाया जाता है ताकि रेंजिंग रॉड को B पर ठीक से फोकस करके लगभग समद्विभाजित किया जा सके
दूरबीन। ऊपरी क्लैंप को कड़ा कर दिया जाता है और बी पर रेंजिंग रॉड को ऊपर की ओर घुमाकर सटीक रूप से द्विभाजित किया जाता है
स्पर्शरेखा पेंच।
वी
10. वर्नियर ए और बी पर रीडिंग नोट की जाती हैं।
11. वर्नियर ए सीधे रीडिंग देता है। लेकिन वर्नियर बी के मामले में, अंतिम रीडिंग से प्रारंभिक रीडिंग घटाकर कोण प्राप्त किया जाता है।
12. पाठ्यांकों को सारणी 1 में सारणीबद्ध रूप में नोट किया गया है।
13. उपकरण का चेहरा बदल दिया जाता है और उपरोक्त प्रक्रिया का पालन किया जाता है।
14. वर्नियर्स की रीडिंग तालिका में नोट की गई है।
15. प्रेक्षणों का माध्य (अर्थात बाएँ और दाएँ चेहरा) वास्तविक कोण <AOB है।
16. इन दो प्रेक्षणों को अपूर्ण समायोजन के कारण किसी भी संभावित त्रुटि को समाप्त करने के लिए लिया जाता है
आईआर.उपकरण
एहतियात: PRECAUTIONS
1. यदि आवश्यक हो, तो प्लेट के बुलबुले को देखने के बाद, पैर के शिकंजे का उपयोग करके केंद्रित किया जाना चाहिए, लेकिन पैर के शिकंजे को प्रारंभिक दृष्टि और अंतिम दृष्टि की रेखा के बीच स्पर्श नहीं किया जाना चाहिए।
2. दूरबीन के माध्यम से देखने से पहले रफ पॉइंटिंग के लिए दूरबीन पर राइफल की जगहों का उपयोग करें।
3. जब क्लैंप स्क्रू अभी भी ढीला हो, तो हाथ से उचित रूप से बंद सेटिंग करें, ताकि टेंगेंट स्क्रू को एक से दो चक्कर लगाने की आवश्यकता न हो।
4. क्लैंप स्क्रू को ज़्यादा न कसें।
5. स्क्रू को मोड़ने के लिए बल न लगाएं।
6. क्षैतिज कोणों को मापते समय डायाफ्राम के लंबवत बाल महत्वपूर्ण होते हैं। ऊर्ध्वाधर बालों को संकेतों को यथासंभव सटीक रूप से द्विभाजित करना चाहिए
नोट:-
तीन तालिका बना कर A एवम B प्रद्र्शित करे
Experiment No.1 To measure of the horizontal angle by general method:-- NOTE:-MAKE THREE TABLE’S AND ATTACH IN YOUR FILES
Experiment No.1
Object : To measure of the horizontal angle by a general method.
Apparatus: Theodolite with stand, ranging rods.
The direct or general method of measuring horizontal angle, consider
the fig. 1 suppose an angle AOB is to be measured. The following
procedure is adopted.
Procedure:
1. Set up the instrument at 0.
(It means that centering and leveling done perfectly) B
2. Keep the vertical circle to be left position. Fig. 1
3. By keeping the lower clamp is fixed. The upper clamp is loosened and by
turning the telescope clockwise, vernier A is set to 00 and vernier B to approximately at 180°.
4. The upper clamp is then tightened. Now by turning the upper tangent screw, verniers A and B are set to
exactly 0° and 180° by looking through the magnifying glass.
5. By keeping the upper clamp fixed, loosen the lower and the telescope is directed to the left hand object. ie. A.
6. The ranging rod A is bisected approximately by properly focusing the telescope and eliminating parallax.
7. Now the lower clamp is tightened and ranging rod A is accurately bisected.
8. By keeping the lower clamp fixed, the upper clamp is loosened.
9. The telescope is turned clockwise to approximately bisect the ranging rod at B by properly focusing the
telescope. The upper clamp is tightened and the ranging rod at B is bisected accurately by turning the upper
tangent screw.
10. The readings on vernier A and B are noted.
11. Vernier A gives the reading directly. But in case of vernier B, the angle is obtained by subtracting the initial reading from the final reading.
12. The readings are noted in tabular form as in table 5.1.
13. The face of the instrument is changed and the above procedure is followed.
14. The readings of the verniers are noted in the table.
15.The mean of the observations (i.e. face left and right) is the actual angle < AOB.
16. The two observations are taken to eliminate any possible error due to imperfect adjustment of the instrument.
Precautions:
1. If required, the plate bubble should be centered after sighting, using foot screws, but the foot screws should not be touched between the initial sighting and the final sighting of the line of sight.
2. Use rifle sights on the telescope for rough pointing before sighting through the telescope.
3. Make a reasonably close setting by hand when the clamp screw is still loose so that the tangent screw will not need to be turned through more than one to two revolutions.
4. Do not over-tighten the clamp screws.
5. Do not apply force for turning the screws.
6. The vertical hair of the diaphragm is important while measuring the horizontal angles. The vertical hair should bisect the signals as accurately as possible
NOTE:-MAKE THREE TABLE’S AND ATTACH IN YOUR FILES
Drainage in Tunnels Drainage & water proofing
Drainage & water proofing Drainage and waterproofing are essential aspects of tunnel construction and...
-
House wiring: A detailed guide It is essential for providing electrical power and connectivity in residential buildings. House wirin...
-
https://docs.google.com/presentation/d/1pxdmCYUu2mMpHXr3mWLg2kiaXDP9BYpt/edit?usp=sharing&ouid=108938057700723052405&rtpof=true...